Product Description:
APC AP8858EU3 230V 18x C13 2x C19 Outlet Vertical Metered Rack PDU
APC Metered Rack Power Distribution Units (PDUs) provide active metering to enable energy optimization and circuit protection. User-defined alarm thresholds mitigate risk with real-time local and remote alerts to warn of potential circuit overloads.
Features:
• Metered Rack PDUs provide power utilization data to allow Data Center Managers to make informed decisions on load balancing and right sizing IT environments to lower total cost of ownership.
• Metered Rack PDUs include real power monitoring, a temperature/humidity sensor port, locking IEC receptacles, and ultra low profile circuit breakers.
• Users can access and configure Metered Rack PDUs through secure Web, SNMP, or Telnet Interfaces which are complimented by APC Centralized Management platforms using InfraStruxure Central, Operations, Capacity, and Energy Efficiency.
• Metered Rack PDUs include real power monitoring, a temperature/humidity sensor port, locking IEC receptacles, and ultra low profile circuit breakers.
• Users can access and configure Metered Rack PDUs through secure Web, SNMP, or Telnet Interfaces which are complimented by APC Centralized Management platforms using InfraStruxure Central, Operations, Capacity, and Energy Efficiency.
Specifications:
Main:
• Colour: Black
• Product or component type: PDU
• PDU type: Metered
• Cord length: 3.00 m
• Number of cables: 1
Complementary:
• Input Voltage: 200 V, 208 V, 230 V
• Height: 90.2 cm
• Width: 5.6 cm
• Output Voltage: 230 V
• Depth: 4.4 cm
• Net weight: 2.93 kg
• Mounting location: Side
• Mounting preference: No preference
• Input Plug Type: IEC 60309 16 A 2P + E
• Mounting mode: Rack-mounted
• Rack units: 0U
• Mounting position: Vertical
• Permissible voltage: 100-240 V
• Max line current: 16 A
• Input current limits: 16 A
• Load capacity: 3700 VA
• Network frequency: 50/60 Hz
• Outlet type and quantity: 18 IEC 60320 C13, 2 IEC 60320 C19
Environment:
• Product certifications: METI Denan, VDE
• Standards: CSA C22.2 No 60950, IEC 60950, UL 60950-1
• Ambient air temperature for operation: -5-60 °C
• Relative humidity: 5-95 %
• Operating altitude: 0-10000 ft
• Ambient air temperature for storage: -25-65 °C
• Storage Relative Humidity: 5-95 %
• Storage altitude 0-15240 m
• Colour: Black
• Product or component type: PDU
• PDU type: Metered
• Cord length: 3.00 m
• Number of cables: 1
Complementary:
• Input Voltage: 200 V, 208 V, 230 V
• Height: 90.2 cm
• Width: 5.6 cm
• Output Voltage: 230 V
• Depth: 4.4 cm
• Net weight: 2.93 kg
• Mounting location: Side
• Mounting preference: No preference
• Input Plug Type: IEC 60309 16 A 2P + E
• Mounting mode: Rack-mounted
• Rack units: 0U
• Mounting position: Vertical
• Permissible voltage: 100-240 V
• Max line current: 16 A
• Input current limits: 16 A
• Load capacity: 3700 VA
• Network frequency: 50/60 Hz
• Outlet type and quantity: 18 IEC 60320 C13, 2 IEC 60320 C19
Environment:
• Product certifications: METI Denan, VDE
• Standards: CSA C22.2 No 60950, IEC 60950, UL 60950-1
• Ambient air temperature for operation: -5-60 °C
• Relative humidity: 5-95 %
• Operating altitude: 0-10000 ft
• Ambient air temperature for storage: -25-65 °C
• Storage Relative Humidity: 5-95 %
• Storage altitude 0-15240 m
Package Contents:
• APC AP8858EU3 PDU
• Installation guide
• Locking input power cord
• Rack mounting brackets
• Serial configuration cable
• Safety guide
• Installation guide
• Locking input power cord
• Rack mounting brackets
• Serial configuration cable
• Safety guide
We will be processing and shipping orders during the holiday period, however our services may be impacted due to the closure of some of our supplier warehouses. Full operations will resume on Monday 6th January. For the fastest response to your queries please email us at sales@elive.co.nz
Additional Details:
-
Stock Availability: 2 In Stock Now
-
Warranty: 2 Years
-
Manufacturer: APC Shop
-
Product Found In: Surge Protectors & Outlets
-
Model Number: AP8858EU3
-
Part Number: DD014509