The Centurion is designed to protect critical computer, communications, industrial, medical and other mission critical equipment. A true online double conversion UPS, the Centurion is
designed to guarantee trouble-free operation of protected equipment in any harsh electrical
environment. Versatile management and hardware options offer the flexibility to build up a power protection solution to fit any application. This range now comes with two sets of sockets on the back, one row of output sockets are programmable meaning that you can shed less important loads. This will leave additional valuable back up time to the equipment that is most critical. This UPS includes a stylish, informative LCD display.
Product Description:
PowerShield Centurion 2000VA/1800W 4 x Outlets Double Conversion True Online Tower UPS
Features:
• True Online Double Conversion
• Wide input voltage range (110-300 VAC)
• Input power factor correction 0.98
• 50Hz/ 60Hz frequency converter mode
• Programmable power outlets
• Emergency power off function (EPO)
• Optional Eco-mode operation for energy saving
• Generator compatible
• Backup time for all models is easily extended by simply plugging additional battery banks
• Charger capacity expansion to 9A for long-run models
• USB, RS232, SNMP and AS400 multiple communications available
• External maintenance bypass available for all models
• N + X parallel redundancy available for 6K/ 10K models
• Monitoring and Shutdown Software included
• Wide input voltage range (110-300 VAC)
• Input power factor correction 0.98
• 50Hz/ 60Hz frequency converter mode
• Programmable power outlets
• Emergency power off function (EPO)
• Optional Eco-mode operation for energy saving
• Generator compatible
• Backup time for all models is easily extended by simply plugging additional battery banks
• Charger capacity expansion to 9A for long-run models
• USB, RS232, SNMP and AS400 multiple communications available
• External maintenance bypass available for all models
• N + X parallel redundancy available for 6K/ 10K models
• Monitoring and Shutdown Software included
Specifications:
• Capacity: 2000VA / 1800W
• Topology: True Online Double Converstion
• Low Line Transfer: 160 VAC / 140 VAC / 120 VAC / 110 VAC ± 5 %based on load percentage 100% - 80 % / 80 % - 70 % / 70 - 60 % / 60 % - 0
• Low Line Comeback: 175 VAC ± 5 %
• High Line Transfer: 300 VAC ± 5 %
• High Line Comeback: 47.5Hz ~ 52.5 Hz or 57Hz ~ 63Hz
• Frequency Range: 47.5Hz ~ 52.5 Hz or 57Hz ~ 63Hz, 47.5Hz ~ 52.5 Hz or 57Hz ~ 63Hz
• Phase: Single phase with ground
• Power Factor: 0.98
• AC Voltage Regulation (Batt. Mode): ± 3%
• Frequency Range (Synchronized Range): 48 ~ 52Hz or 57 ~ 63Hz
• Frequency Range (Batt. Mode): 50Hz ± 0.25Hz or 60Hz ± 0.3Hz
• Harmonic Distortion: 4 % THD (Linear Load), 7 % THD (Non-linear Load)
• Inverter to Bypass: 4 ms (Typical)
• ECO Mode: 88%
• Battery Mode: 83%
• Battery Type: 12V*9AH(x6)
• Typical Recharge Time: 4 hours recover to 90% capacity
• Charging Current (max.): 1.0A
• Charging Voltage: 82.1 VDC ±1%
• Full Protection: Overload, discharge, thermal, short circuit and overcharge protection
• Interface: USB or RS232 as standard, Intelligent slot for PSSNMP or PSAS400 dry contact
• Software: Power Shield NetGuard Software - supports Windows based operating Systems, Linux, Unix & Mac
• LCD Displays / Alarms: UPS Status, Load Level, Battery Level, Input/Output Voltage, Battery Time Remaining and Fault Indicators
• Audible Alarm: Battery Mode, Low Battery, Overload, Fault
• Temperature: 0- 40°C
• Humidity: 20-90 % (RH Non-condensing)
• Noise Level: Less than 45dBA @ 1 Meter
• Safety: EN62040-1-1 2003, IEC60950-1-1
• EMS: EN62040-2 2006
• RoHS: Directive 2001 / 65 / EU
• Dimensions: 425mm x 190mm x 335mm
• Weight: 28kg
• Topology: True Online Double Converstion
• Low Line Transfer: 160 VAC / 140 VAC / 120 VAC / 110 VAC ± 5 %based on load percentage 100% - 80 % / 80 % - 70 % / 70 - 60 % / 60 % - 0
• Low Line Comeback: 175 VAC ± 5 %
• High Line Transfer: 300 VAC ± 5 %
• High Line Comeback: 47.5Hz ~ 52.5 Hz or 57Hz ~ 63Hz
• Frequency Range: 47.5Hz ~ 52.5 Hz or 57Hz ~ 63Hz, 47.5Hz ~ 52.5 Hz or 57Hz ~ 63Hz
• Phase: Single phase with ground
• Power Factor: 0.98
• AC Voltage Regulation (Batt. Mode): ± 3%
• Frequency Range (Synchronized Range): 48 ~ 52Hz or 57 ~ 63Hz
• Frequency Range (Batt. Mode): 50Hz ± 0.25Hz or 60Hz ± 0.3Hz
• Harmonic Distortion: 4 % THD (Linear Load), 7 % THD (Non-linear Load)
• Inverter to Bypass: 4 ms (Typical)
• ECO Mode: 88%
• Battery Mode: 83%
• Battery Type: 12V*9AH(x6)
• Typical Recharge Time: 4 hours recover to 90% capacity
• Charging Current (max.): 1.0A
• Charging Voltage: 82.1 VDC ±1%
• Full Protection: Overload, discharge, thermal, short circuit and overcharge protection
• Interface: USB or RS232 as standard, Intelligent slot for PSSNMP or PSAS400 dry contact
• Software: Power Shield NetGuard Software - supports Windows based operating Systems, Linux, Unix & Mac
• LCD Displays / Alarms: UPS Status, Load Level, Battery Level, Input/Output Voltage, Battery Time Remaining and Fault Indicators
• Audible Alarm: Battery Mode, Low Battery, Overload, Fault
• Temperature: 0- 40°C
• Humidity: 20-90 % (RH Non-condensing)
• Noise Level: Less than 45dBA @ 1 Meter
• Safety: EN62040-1-1 2003, IEC60950-1-1
• EMS: EN62040-2 2006
• RoHS: Directive 2001 / 65 / EU
• Dimensions: 425mm x 190mm x 335mm
• Weight: 28kg
We sell a large range of UPS devices including commercial grade models requiring a licensed electrician, and/or additional cables/power requirements for installation. Warranty periods on UPS devices will exclude the battery, as they are a consumable item. We will be processing and shipping orders during the holiday period, however our services may be impacted due to the closure of some of our supplier warehouses. Full operations will resume on Monday 6th January. For the fastest response to your queries please email us at sales@elive.co.nz
Additional Details:
-
Stock Availability: 34 In Stock Now
-
Warranty: 2 Years
-
Manufacturer: Power Shield Shop
-
Product Found In: UPS Devices
-
Model Number: PSCE2000
-
Part Number: CD03310