Product Description:
Vertiv Liebert GXT5 8000VA 8000W 8 Outlet Online Double Conversion Rack/Tower UPS
The Vertiv Liebert GXT5 UPS is an online double conversion UPS solution which offers premium power outage protection and continuous power conditioning in a compact and flexible deployment system.
Features:
Unity Power Factor (PF=1.0):
More active power available so more loads can be connected versus lower power factor systems thus saving space and cost.
High efficiency up to 95% in on-line mode:
Higher efficiency means optimized energy management and lower heat dissipation, thus providing energy and cost savings.
Even high efficiency up to 98% in Active ECO mode:
Superior protection with maximum efficiency.
Colored graphic LCD display with gravity orientation:
User friendly interface to know UPS status and configuration.
External Battery cabinets with auto detection:
Be confident your UPS is set up correctly to report available run time when used with external battery cabinets.
Rack/Tower design with short depth and flexible to install:
A more compact UPS that will use less floor space, and leaves more space available for data equipment in a rack.
More active power available so more loads can be connected versus lower power factor systems thus saving space and cost.
High efficiency up to 95% in on-line mode:
Higher efficiency means optimized energy management and lower heat dissipation, thus providing energy and cost savings.
Even high efficiency up to 98% in Active ECO mode:
Superior protection with maximum efficiency.
Colored graphic LCD display with gravity orientation:
User friendly interface to know UPS status and configuration.
External Battery cabinets with auto detection:
Be confident your UPS is set up correctly to report available run time when used with external battery cabinets.
Rack/Tower design with short depth and flexible to install:
A more compact UPS that will use less floor space, and leaves more space available for data equipment in a rack.
Specifications:
Ratings:
• 8,000 VA / 8,000 W
Input AC Parameters:
• Operating Frequency, Nom : 50 or 60 Hz (Factory default is 50 Hz )
• Factory Default Voltage: 230 VAC
• Operating Voltage Range Without Battery Operation: 176 to 288 VAC (100 to 176 VAC with power derating)
• Maximum Allowable Voltage: 288 VAC
• Input Frequency Without Battery Operation: 40 to 70 Hz
Output AC Parameters:
• AC-AC Efficiency: 94.5%
• User-configurable Voltage: 200/208/220/230/240 VAC
• Factory Default Voltage: 230 VAC
• Frequency: 50 Hz or 60 Hz, Nominal
• Waveform: Pure Sinewave
• Output Power Connection: Output terminal block
• Main Mode Overload: >150% minimum 200 ms, 125 – 150% for 60 seconds; 105 – 125% for 5 minutes; ≤ 105% continuous
Internal Battery:
• Charger Current: 2.25 A (default), maximum 8 A
• Type: Valve-regulated, non-spillable, lead acid
• Qty x V x Rating: 2 x 8 x 12V x 9.0 AH
• Back-up Time at Full Load: 3.5
• Back-up Time at Half Load: 9.5
Bypass Protection Limits:
• Upper-limit Selections: + 10%, + 15%, + 20%; default + 10%.
• Lower-limit Selections: - 10%, - 15%, - 20%; default - 15%
• Disable-bypass Operation: When the input frequency prevents synchronous operation
General:
• Operating Temperature: Full power up to 40 ºC (up to 50 ºC with derating)
• Storage Temperature: - 15 to + 40 ºC
• Relative Humidity: 0 – 95% non-condensing
• Operating Elevation: Up to 3,000 m (9,842.5 ft) at 25°C (77°F) without derating
• Audible Noise: < 55 dBA
Dimensions and Weight:
• Dimensions (W×D×H): 430 × 630 × 217 mm
• Unit Weight: 74.5 kg
• 8,000 VA / 8,000 W
Input AC Parameters:
• Operating Frequency, Nom : 50 or 60 Hz (Factory default is 50 Hz )
• Factory Default Voltage: 230 VAC
• Operating Voltage Range Without Battery Operation: 176 to 288 VAC (100 to 176 VAC with power derating)
• Maximum Allowable Voltage: 288 VAC
• Input Frequency Without Battery Operation: 40 to 70 Hz
Output AC Parameters:
• AC-AC Efficiency: 94.5%
• User-configurable Voltage: 200/208/220/230/240 VAC
• Factory Default Voltage: 230 VAC
• Frequency: 50 Hz or 60 Hz, Nominal
• Waveform: Pure Sinewave
• Output Power Connection: Output terminal block
• Main Mode Overload: >150% minimum 200 ms, 125 – 150% for 60 seconds; 105 – 125% for 5 minutes; ≤ 105% continuous
Internal Battery:
• Charger Current: 2.25 A (default), maximum 8 A
• Type: Valve-regulated, non-spillable, lead acid
• Qty x V x Rating: 2 x 8 x 12V x 9.0 AH
• Back-up Time at Full Load: 3.5
• Back-up Time at Half Load: 9.5
Bypass Protection Limits:
• Upper-limit Selections: + 10%, + 15%, + 20%; default + 10%.
• Lower-limit Selections: - 10%, - 15%, - 20%; default - 15%
• Disable-bypass Operation: When the input frequency prevents synchronous operation
General:
• Operating Temperature: Full power up to 40 ºC (up to 50 ºC with derating)
• Storage Temperature: - 15 to + 40 ºC
• Relative Humidity: 0 – 95% non-condensing
• Operating Elevation: Up to 3,000 m (9,842.5 ft) at 25°C (77°F) without derating
• Audible Noise: < 55 dBA
Dimensions and Weight:
• Dimensions (W×D×H): 430 × 630 × 217 mm
• Unit Weight: 74.5 kg
We sell a large range of UPS devices including commercial grade models requiring a licensed electrician, and/or additional cables/power requirements for installation. Warranty periods on UPS devices will exclude the battery, as they are a consumable item.
Additional Details:
-
Stock Availability: Out of Stock!
-
Warranty: 3 Years
-
Manufacturer: Vertiv Shop
-
Product Found In: UPS Devices
-
Model Number: GXT5-8000IRT5UXLN
-
Part Number: DV16171